Cisco Systems EDFA2 Operations Manual Page 175

  • Download
  • Add to my manuals
  • Print
  • Page
    / 280
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 174
FINAL DRAFT - CISCO CONFIDENTIAL
9-27
Cisco ONS 15216 EDFA2 Operations Guide
78-16033-01
Chapter 9 TL1 Commands
TL1 Commands and Autonomous Messages
9.7.19 REPT ALM ENV
Command REPT ALM ENV
Reports when a power bus alarm is logged or cleared (derived from cerent15216EdfaAlarmState).
Syntax
<sid> <date> <time>
<almcde> <atag> REPT ALM ENV
"<aid>:<ntfcncde>,<condtype>,<ocrdat>,<ocrtm>,<conddescr>"
;
Example 9-21 REPT ALM ENV Message
Amp01 2001-06-18 14:48:44
** 141 REPT ALM ENV
"PWR-A:MN,PWRBUSA,6-18,14-48-44,\"Power Bus A Alarm\""
;
Table 9-26 REPT ALM ENV Syntax Description
Parameter Syntax Description
almcde The alarm severity code for the TL1 message. Possible values
are:
*C Critical alarm.
** Major alarm.
*Minor alarm.
A No alarm. Occurs only when ntfncde is NA.
atag 0 - 999 An integer between 0 and 999 used as a sequence number in
autonomous messages .
aid Possible values are:
PWR-A Affecting Power Bus A (or both A and B).
PWR-B Affecting Power Bus B.
conddescr Detailed text description of the event. The conddescr is 1 to 64
characters of ASCII text. See condtype below.
condtype Condition type identifies the type of alarm (maps to
cerent15216EdfaLogEventID). Possible condtype and
corresponding conddescr (in quotes) are:
PWRBUSA Power Bus A (voltage) Alarm
(cerent15216EdfaAlarmPowerBusA).
PWRBUSB Power Bus B (voltage) Alarm
(cerent15216EdfaAlarmPowerBusB).
date yyyy-mm-dd Date of origination of TL1 message.
Page view 174
1 2 ... 170 171 172 173 174 175 176 177 178 179 180 ... 279 280

Comments to this Manuals

No comments