15
Figure 11 AC Power Supply for the Cisco ASR 1002 Router
Table 1 describes the AC power supply LEDs on the Cisco ASR 1002 Router.
Table 1 Cisco ASR 1002 Router AC Power Supply LEDs
Note To connect an AC power supply to the Cisco ASR 1002 Router, follow the steps in Installing the AC Power Supply,
page 31.
Connect DC Power to the Cisco ASR 1002 Router
The DC power supply input connector is a euro-style terminal block. A means to provide strain relief to the input wires is
provided on the power supply. The connection order is negative (), positive (+), and GND.
1
Chassis ESD socket
5
AC power supply fan
2
AC power supply slot number 0
6
AC power supply captive installation screw
3
AC power supply On (I) /Off (O) switch
7
AC power supply slot number 1
4
AC power supply LEDs
8
AC power inlet
LED Label LED Color Description
INPUT OK Power supply activity Green The AC power supply input voltage is greater than 85V.
None The AC input voltage is less than 70V or the power
supply is turned off.
Flashing For an AC input voltage between 70V and 85V the
INPUT OK LED can be either on, off, or flashing
FAN OK Power supply fan activity
A bi-color LED indicates
fan status.
Green When all fans are operational.
Red When a fan failure is detected.
OUTPUT FAIL Power supply activity Red LED is off to signal that the DC output voltages are
within the normal operating range. Output voltage
between the minimum and maximum limits will not
create an output fail alarm and output voltages below
the minimum or above the maximum will create an
output fail alarm.
OUTPUT INPUT
FAIL
OK OK
FAN OUTPUT INPUT
FAIL
OK OK
FAN
This unit might have more than
one power supply connection.
All connections must be removed
to de-energize the unit.
This unit might have more than
one power supply connection.
All connections must be removed
to de-energize the unit.